中国口腔颌面外科杂志 ›› 2024, Vol. 22 ›› Issue (1): 58-62.doi: 10.19438/j.cjoms.2024.01.010

• 论著 • 上一篇    下一篇

非共面照射野在舌癌放疗中对脊髓和下颌骨重点保护的效果评价

石慧烽, 涂文勇, 胡海生, 樊文慧, 毕帆, 劳峥   

  1. 上海交通大学医学院附属第九人民医院 口腔颌面-头颈肿瘤科,上海交通大学口腔医学院,国家口腔医学中心,国家口腔疾病临床医学研究中心,上海市口腔医学重点实验室,上海市口腔医学研究所,上海市头颈肿瘤诊治和转化医学中心,上海 200011
  • 收稿日期:2023-08-15 修回日期:2023-11-04 出版日期:2024-01-20 发布日期:2024-02-05
  • 通讯作者: 涂文勇,E-mail:tu4you@163.com

Non-coplanar irradiation fields in the application of spinal cord and mandible protection during tongue cancer radiotherapy

SHI Hui-feng, TU Wen-yong, HU Hai-sheng, FAN Wen-hui, BI Fan, LAO Zheng   

  1. Department of Oromaxillofacial Head and Neck Oncology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine; College of Stomatology, Shanghai Jiao Tong University; National Center for Stomatology; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology; Shanghai Research Institute of Stomatology; Shanghai Center of Head and Neck Oncology Clinical and Translational Science. Shanghai 200011, China
  • Received:2023-08-15 Revised:2023-11-04 Online:2024-01-20 Published:2024-02-05

摘要: 目的: 在舌癌术后放疗计划中重点保护脊髓和下颌骨的前提下,通过比较共面野与非共面野计划两者放疗剂量分布的差异,探讨非共面照射野在放疗计划中对脊髓和下颌骨的重点保护效果,从而选择合理放疗方案,以应对舌癌复发需再次放疗的可能性。方法: 选择上海交通大学医学院附属第九人民医院口腔颌面-头颈肿瘤科在2018年2月—2023年2月收治的15例舌癌术后放疗患者作为研究对象,采用实际治疗的靶区作为计算目标,正常组织剂量限值参照国家标准,在其他参数保持不变的前提下,仅仅变动脊髓以及下颌骨的限量函数。函数采用serial函数,限量由低到高分为20、25、30、35、40,在Monaco计划系统中自动计算,对计划各个参数进行评价(靶区CI、HI、D98、D95、D5、D2),正常组织脊髓的最大量,腮腺、喉、下颌骨的平均量。采用SPSS 20.0软件包对数据进行统计学分析。结果: 非共面野的各项评价指标优于共面野计划。共面野计划在serial函数限值为20、25时,靶区评价指标D98、D95、D5、D2形成剂量趋势曲线存在发散状态,靶区归一性较差。随着限值提高,2组计划的靶区剂量趋势曲线相差变小,靶区归一性基本统一。统计结果显示,相对于非共面野计划,共面野计划在seiral函数为20、25时,脊髓、左右侧腮腺、喉、下颌骨以及靶区的CI、HI的结果较差,2组差异有统计学意义(P<0.05);特别在serial函数为20时差异值最大,HI指数差异为7.7%,CI差异为14%。随着限值提高,2组数据差异逐渐变小,多数评价指标差值有统计学意义(P<0.05)。结论: 舌癌术后放疗计划中,在脊髓、下颌骨限量较为严格时,2组计划剂量差异较大,计划射野时建议选择非共面角度。随着限量提高,差异性逐渐变小。虽然多数指标仍存在统计学差异,但鉴于非共面野有转床的误差存在,计划射野时,可根据患者情况以及机器精度进行合理选择。

关键词: 非共面照射, Monaco治疗计划系统, 舌癌, 放疗

Abstract: PURPOSE: In postoperative radiotherapy planning for tongue cancer, with a focus on protecting the spinal cord and mandible, this study aims to explore the application effectiveness of non-coplanar radiation fields in the protection of the spinal cord and mandible in radiotherapy planning by comparing the differences in dose distribution between coplanar and non-coplanar plans. The goal is to select a reasonable radiotherapy plan to address the possibility of tongue cancer recurrence requiring re-irradiation. METHODS: Fifteen postoperative tongue cancer patients admitted to the Department of Oromaxillofacial Head and Neck Oncology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine from February 2018 to February 2023 were selected as the study subjects. The actual treatment target volume was used as the calculation target, and the dose limits for normal tissues were reference to national standards. With other parameters fixed, only the constraint functions for the spinal cord and mandible were varied. Serial functions were used, and the limits ranged from low to high: 20, 25, 30, 35, and 40. The limits were automatically calculated in the Monaco treatment planning system, and various parameters of the plans were evaluated, including target volume(CI, HI, D98, D95, D5, D2) and the maximum dose to the spinal cord, mean dose to the parotid glands, larynx, and mandible in normal tissues. SPSS 20.0 software package was used for data analysis. RESULTS: The evaluation indicators for the non-coplanar plan were superior to those for the coplanar plan. For the coplanar plan, when the serial function limits were set at 20 and 25, the dose distribution trends of the target volume indicators(D98, D95, D5, D2) showed divergence, and the target volume homogeneity was poor. As the limits increased, the differences in the dose distribution curves of the two plans decreased, and the homogeneity of the target volume became relatively uniform. The statistical results showed that compared to the non-coplanar plan, the coplanar plan had poorer results in terms of the spinal cord, bilateral parotid glands, larynx, mandible, and the CI and HI of the target volume when the serial function limits were set at 20 and 25. The differences between the two groups were statistically significant (P<0.05), with the greatest difference observed at a serial function limit of 20, where the difference in the HI index was 7.7% and the CI difference was 14%. As the limits increased, the differences between the two groups gradually decreased, and most of the differences in the evaluation indicators were statistically significant(P<0.05). CONCLUSIONS: In postoperative radiotherapy planning for tongue cancer, when the constraints on the spinal cord and mandible are strict, there is significant difference in dose distribution between the two plan groups. It is recommended to choose non-coplanar angles when planning the radiation fields. As the limits increase, the differences decrease gradually. Although most indicators still show statistical differences, considering the potential positional errors associated with non-coplanar fields, the selection of planning fields should be based on patient-specific factors and machine accuracy.

Key words: Non-coplanar irradiation, Monaco treatment planning system, Tongue cancer, Radiotherapy

中图分类号: